Recent Changes - Search:

HySafe

SBEP

PmWiki

pmwiki.org

edit SideBar

Deflagration Sphere 02

Experiment ID UU-02
Short Description Deflagration of large-scale (initial radius 10 m) hemispherical stoichiometric hydrogen-air mixture in open atmosphere ignited at the centre of hemisphere.
   

10 m radius hemisphere with hydrogen-air mixture.    Flame front contours with time.

What phenomena were studied Flame front propagation and pressure generation after point ignition of initially quiescent mixture.
What phenomena / effects can be studied Flame propagation dynamics in open atmosphere, pressure wave generation and propagation.
Instrumentation Pressure transducers, video cameras to obtain flame contours.
Test variables
Data description / Data completeness Snapshots of flame contours up to 20 m and average flame front radius in time, pressure-time transients at 2, 2.4, 5, 6.5, 8, 18, 25, 35, 60, 80 m from the ignition point.
Data availability Experiment performed by HySafe partner (FhG-ICT)
Source of data / Reference
  1. Schneider H., Pförtner H. PNP-Sicherheitssofortprogramm, Prozeßgasfreisetzung-Explosion in der Gasfabrik und Auswirkungen von Druckwellen auf das Containment. Dezember 1983.
  2. Becker T., Ebert F., Vergleich zwischen Experiment und Theorie der Explosion großer, freier Gaswolken. Chem.-Ing.-Tech., V.57, N.1, pp.42-45, 1985
Why were chosen Largest ever experiment on hydrogen-air deflagration in open atmosphere.
Relevance to the project purposes One of the possible scenarios in practice is hydrogen-air deflagration in open atmosphere.