Experiment ID
| HYCOM-MC003
|
Short Description
| Test 1 of 3 (MC003, MC012, R0489_09). Combustion experiments have been carried out in obstructed tube of 174 mm i.d. and 12.2 m long (DRIVER facility). Repeatable obstacles with blockage ratio BR=0.6 at distances equal to i.d. Hydrogen/air mixture with concentration of 10% H2 was tested.
|
What phenomena were studied
| Flame acceleration in the presence of obstructed channel
|
What phenomena / effects can be studied
| Unstable subsonic flame with local quenching
|
Instrumentation
| Three types of pressure transducers (1) piezoresistive transducers D06 (one-membrane type, frequency 1 kHz), (2) piezoresistive transducers PPD1.6 (two-membrane type, frequency 100 kHz), and (3) piezoelectric transducers PCB-H113A (frequency 100 kHz).
Collimated germanium photodiodes (up to 23) for measurement of the time-of arrival of the flame front. Time resolution of 10 µs. The photodiodes were not calibrated, and they provided flame radiation intensity qualitatively.
|
Test variables
| Hydrogen concentration
|
Data description / Data completeness
| All pressure and photo-diode recordings in digital form
|
Data availability
| Publicly accessible
|
Source of data / Reference
| Technical Report: EU Project HYCOM, 2004 (to be published)
|
Why were chosen
| Very well instrumented, complete description
|
Relevance to the project purposes
| Series of three experiments can address effect of mixture composition on flame propagation in obstructed geometry. Has primary importance for code validation.
|
Experimental data
|
|
Results of simulations
|
|